1, in the high: choose built-in cable tubing ﹑ ﹑ ﹑ water pipe like most coarse one as a reference height, plus at least 10% of the height of the space as towline high if the actual height of the overlap after overlap as the reference height.
2, inner width: choose some thick cable tubing ﹑ ﹑ ﹑ pipes and other pipe having an outer diameter of the towline in width and as a reference, and leave at least 10% of the width of the space.
3, bending radius: choose built-in cable tubing ﹑ ﹑ ﹑ pipes and other pipe bending radius of the largest as a reference value, and leaving more than 10% of the space.
Cableveyor built-in cable tubing ﹑ ﹑ ﹑ water pipe placement guidelines:
1, it should leave 15% of the remaining space for built-in cable ﹑ tubing and other activities are free, in the radial direction of the towline does not produce tension.
2, the diameter difference between the large wire should be laid separately, weight distribution, can be separated sheet separately if necessary.
3, high-speed or high-frequency operation, to try to make the wires apart from each other on a level, do not make it over another, the more time the cable ﹑ ﹑ tracheal tubing and other recommended separators.